DP7000 PDU Testing System Application

Users may have many testing requirements for PDU testing, in addition to wiring harness testing requirements, there are also some functional tests. For example, contactor function testing, airtightness testing, PDU load testing, component testing and other functions.

PDUCharging-Gun-Wire-Harness-Test

Feature:

  • Suitable for online full inspection during PDU mass production process
  • 8 sets of control cards per control card (multiple cards can be added) for control circuit connection, testing resistance, high-voltage insulation, etc
  • 32 points per card (with the option to add multiple cards) for measuring on/off circuits, and can determine the upper and lower limit resistance values for each set of test on/off settings
  • 32 points per card (multiple cards can be added) for measuring resistance, and tests the resistance value of each circuit under the measurement conditions of 0-40V 0-2A,
  • Minimum resistance display 1uΩ, four wire measurement can display voltage drop
  • The equipment can provide a withstand voltage of 0-3.5KV insulation 1KV test before and after the control circuit is closed, and can set leakage current insulation upper and lower limits
  • The system provides the communication conditions required for EMS and BMS communication control testing
  • Hardin interface for quick replacement
  • The equipment adopts pure computer editing, testing, storage and other operations

Different configuration available for DP7000 PDU Testing System

  • Single electrical control box
  • 2-in-1 electrical control box
  • Multi in one electrical control box
  • Three in one electrical control box
Test items and specifications Test ranges
OS test 1KΩ-10MΩ(+2%)
Conducting resistance test 1uΩ-1.5KΩ(+2%)
Relay 8 sets of control boards can be expanded
Relay status Test multiple groups OS states
AC/DC hipot AC 10V-3500V/5000V DC10V-5000V/6000V
DC insulation 1000V(50KΩ-10000MΩ)
Diode Forward:<1.0V Reverse: max.40V (optional)
Capacitance 10nF-20mF (± 5%) (optional)
Inductance 10nH-20KH (± 2%) (optional)
Test voltage 0.2-40VDC step 0.1V
Test current Max.2A DC step 1mA
The points number of DP7000 cable harness tester in PDU testing system mainly depends on the PIN points
OS test 1KΩ
Resistance <5mΩ
Voltage resistance 3KV <1mA
Insulation 1KV>500MΩ
PDU testing logic control 0-40V voltage control
8 cards More card numbers can be selected
Logic control can be controlled by conduction High voltage demand completed opening and closing
Voltage drop test (Test condition 40v 2A)
Point selection 32P/64P/128P/256P/512P/1024P optional, can be expanded
Author picture
Welcome To Share This Page:
Get A Free Quote Now !
Contact Form Demo (#3)
Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)
If you have any questions, please do not hesitate to contatct with us.
new-building-for-Wire-harness-tester-project